BLUE M
Blue M - - DC 146 Series Industrial Ovens, Models DC, DCW, DCI, DCC
Page 30
Making the Power Supply Connection to the Chamber:
A main power disconnect switch is normally not provided with your chamber. We recommend that a fused
disconnect switch on a separate branch circuit be installed as the power source to your chamber, in
accordance with all national and local electrical codes. Reference your Electrical Schematic or your serial tag
for all electrical requirements.
The power supply connection is made to the main power cables inside the power supply junction box located
at the rear left side of the oven.
Warning! High Accessible Current – An Earth connection is essential before connecting the power
supply. Make sure equipment is properly grounded in accordance with all codes.
Warning! Make sure that all electrical wiring is properly installed in accordance with all National
and Local Electric Codes. Make sure all connections are secure.
Machinery Section Rear Views:
Rear views of machinery sections are shown for a range of oven sizes from large to small. These include the
Models DC1406, DC336, and DCC206.
MACHINERY SECTION – MODEL DC1406
Power Supply
Junction Box
Main Circuit Breaker
Heater Connections
Circ. Motor
Control Panel Assembly
Diff. Air
Press. Sw.
Model DC1406
Heater Power SSRs