Printed in the Federal Republic of Germany TR-Electronic GmbH 2017, All Rights Reserved
06/29/2023 TR-ECE-BA-DGB-0135 v07 Page 167 of 200
Connection path, Packed EPATH with 8 bit class
0x20
0x23
0x24
0x01
0x30
0xC8
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #200
8.4.3.41.2 Attribute 0xC9, Preset Input 1
Preset Input 1 defines the preset value to be set when the hardware input "Preset1"
is performed.
ULINT
Preset Value 1
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
2
39
to 2
32
2
47
to 2
40
2
55
to 2
48
2
63
to 2
56
Access
Set / Get
Lower limit
0
Upper limit
Value within the range from 0 to programmed
measuring length in steps – 1
Default
0
Connection path, Packed EPATH with 8 bit class
0x20
0x23
0x24
0x01
0x30
0xC9
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #201
8.4.3.41.3 Attribute 0xCA, Preset Input 2
Preset Input 2 defines the preset value to be set when the hardware input "Preset2"
is performed.
ULINT
Preset Value 2
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
2
7
to 2
0
2
15
to 2
8
2
23
to 2
16
2
31
to 2
24
2
39
to 2
32
2
47
to 2
40
2
55
to 2
48
2
63
to 2
56
Access
Set / Get
Lower limit
0
Upper limit
Value within the range from 0 to programmed
measuring length in steps – 1
Default
0
Connection path, Packed EPATH with 8 bit class
0x20
0x23
0x24
0x01
0x30
0xCA
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #202