EasyManua.ls Logo

TR-Electronic CK-58 - User Manual

TR-Electronic CK-58
112 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
43777D, 43777E, 437791, 437792, 4377C8, 4377C9
437A76, 437A77, 437A72, 437A73, 437A7C, 437A7D
TR - ECE - BA - DGB - 0036 - 16 11/05/2018
Benutzerhandbuch
User Manual
Seite 2 - 56
Page 57 -112
D
GB
_Zusätzliche Sicherheitshinweise
_Installation
_Inbetriebnahme
_Konfiguration / Parametrierung
_Störungsbeseitigung und
Diagnosemöglichkeiten
_Additional safety instructions
_Installation
_Commissioning
_Configuration / Parameterization
_Troubleshooting / Diagnostic options
CK
-58
CEK
-58
COK
-58
Absolute Encoder C__-58
-58
-58
-58
CH-58 / CS-
58
CEH-58 / CES-
58
COH-58 / COS-
58
Explosionsschutzgehäuse /
Explosion Protection Enclosure
_
A**58*
_
A**70*

Table of Contents

Other manuals for TR-Electronic CK-58

Questions and Answers

  • S
    smithraymondAug 10, 2025
    Why does my TR-Electronic CK-58 have position skips?
    • S
      simonrogerAug 10, 2025
      Position skips in the TR-Electronic Media Converter measuring system can stem from strong vibrations, electrical faults (EMC), or extreme axial and radial load on the shaft. To address vibrations, consider using 'shock modules' to dampen impacts and shocks, especially on presses. For electrical faults, isolated flanges and plastic couplings, along with twisted-pair cables for data and supply, may help. Ensure shielding and wire routing adhere to PROFIBUS construction guidelines. To mitigate mechanical stress on the shaft, use couplings. If position skips persist after these measures, the measuring system might need replacement.
  • X
    Xavier AllenAug 25, 2025
    What to do if PROFIBUS runs without TR-Electronic CK-58 Media Converter but fails when connected?
    • E
      epittmanAug 25, 2025
      If the PROFIBUS runs when the TR-Electronic Media Converter measuring system is disconnected but faults occur when the bus hood is plugged in, the PROFIBUS Data A and Data B might be switched. Verify all connections and lines related to the wiring of the measuring system to ensure they are correctly configured.