7.1 Overview
7.1.1 CEx-58, TR09AAAB.GS_
Configuration Operating parameters
Length
Features
PNO Class 1-16
Page 81
- Count direction
16 bit IN
-
No measuring system scaling, the measuring
system has the base resolution according to the
nameplate
- 16 byte diagnosis data
- Count direction
PNO Class 1-32
Page 81
- Count direction
32 bit IN
PNO Class 2-16
Page 82
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
16 bit IN
16 bit OUT
- Max. steps per revolution 8192, if higher
resolutions are required, one of the TR-Modes
must be used
-
Measuring system scaling is possible, however
the number of steps / revolution must be an
integer and the number of revolutions an
exponent of 2
- Preset adjustment via the bus
- Count direction
PNO Class 2-32
Page 83
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
32 bit IN
32 bit OUT
TR-Mode,
Position
Page 84
- Count direction
- Commissioning diagnostics
- Short Diagnostics
- Total measuring range
- Revolutions numerator
- Revolutions denominator
- Code PROFIBUS-Interface
- Lower limit switch
- Upper limit switch
32 bit IN
32 bit OUT
- Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not
an exponent of 2).
- Preset adjustment via the bus
- Count direction
-
Output code programming
-
Soft limit switch function
TR-Mode,
- Position +
- Velocity
Page 85
- Count direction
- Commissioning diagnostics
- Short Diagnostics
- Total measuring range
- Revolutions numerator
- Revolutions denominator
- Code PROFIBUS-Interface
- Lower limit switch
- Upper limit switch
- Velocity
32 bit IN
16 bit IN
32 bit OUT
- Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not
an exponent of 2).
- Preset adjustment via the bus
- Count direction
- Output code programming
- Soft limit switch function
- Velocity output
* from the bus master perspective

Table of Contents

Other manuals for TR-Electronic CK-58

Related product manuals