Parameterization and configuration
TR-Electronic GmbH 2004, All Rights Reserved Printed in the Federal Republic of Germany
Page 84 of 112 TR - ECE - BA - DGB - 0036 - 16 11/05/2018
7.6 TR-Mode Position
Availability
● CEx-58, TR09AAAB.GS_
Configuration data
● 0xF1: 1 double word input data for position value, consistent
1 double word output data for preset adjustment value, consistent
Data Exchange
X+0
Preset execution with rising edge, see page 89
Parameter data, [x] = Default, Byte-Order = Big Endian
1
Count direction Bit Bit 0
0: increasing values [x]
1: decreasing values
90
Short diagnostics
(16 Byte)
Bit Bit 1
92
Commissioning
diagnostics
Bit Bit 2
0: switched off [x]
1: switched on
90
2 Teach-In function Unsigned8 Bit 1-0
00: switched off no status [x]
10: switched off with status
11: switched on with status
91
3-6 Total measuring range Unsigned32
Total measuring range in steps
Default = 16777216 steps
95
7-10 Revolutions numerator Unsigned32
Number of revolutions as fraction
Default = 4096 (numerator)
96
11-12 Revolutions denominator Unsigned16
Number of revolutions as fraction
Default = 1 (denominator)
96
14
Code PROFIBUS-
Interface
Unsigned8 Bit 1-0
01: Binary [x]
98
23-26 Lower limit switch Unsigned32
Position value for lower limit switch
Default = 0
98
27-30 Upper limit switch Unsigned32
Position value for upper limit switch
Default = 4096
98