EasyManua.ls Logo

Trane Technologies 4TTV8060A1000B - Page 51

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4T-V8-SF-1M-EN
51
Technician Monitor Menu
TThheeMMoonniittoorrMMeennuuddiissppllaayyssiinnffoorrmmaattiioonnoonnSSyysstteemm
ssttaattuuss,, DDrriivveessttaattssaannddtthheeSSyysstteemmTTaacchhoommeetteerr..
Continued on next page
Scan to see a
video about the
CDA Monit
or
Menu
CONTROL
MENU
Heat Pump Only
PWM value on line 2 between 0-99
CDTS (Comp Dome Temp Sensor)
SPS (Suction Pressure Sensor)
LTS (Liquid Temp Sensor) Future Option
LIQ (Liquid Pressure Sensor) Future Option
If LIQ SENSE and LIP PRESSURE are both installed
Future Option
STS (Suction Temp Sensor)
CTS (Coil Temp Sensor)
ODS (Ambient Temperature Sensor)
Cycling stage will display “Stage 1”
Modulating stage will display % Demand
ALERT MENUMONITOR MENU
SYSTEM COMP DEMAND
XXX%
COMP SPEED
XXX RPM
SOV POSITION
HEAT/COOL
EXTERNAL SWT
CLOSED/OPEN/IGNORE
AMB TEMP
XXX F
EXT OD TEMP
XXX F
COIL TEMP
XXX F
SUCT T SENSE
XXX F
SUC PRESS
XXX PSIG
SUPERHEAT
XXX F
LIQ T SENSE
XXX F
LIQ PRESS
XXX PSIG
SUBCOOLING
XXX F
DOME TEMP
XXX F
MOTOR PWM
XX
EEV POSITION
XXX/YYY STEPS
EEV TYPE
TP/TT