EasyManua.ls Logo

Trane Technologies 4TWV8049A1000B User Manual

Trane Technologies 4TWV8049A1000B
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SSAAFFEETTYYWWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
April 2020
44TT--VV88--SSFF--11MM--EENN
Variable Speed ComfortLink™ II
Heat Pumps and Air Conditioners
4TWV8024A1000B
4TWV8036A1000B
4TWV8037A1000B
4TWV8048A1000B
4TWV8049A1000B
4TWV8060A1000B
4TTV8024A1000B
4TTV8036A1000B
4TTV8037A1000B
4TTV8048A1000B
4TTV8060A1000B
NNoottee:: “Graphics in this document are for representation only. Actual
model may differ in appearance.”
Scan t o see h el p
videos on this
product
Service Facts
Question and Answer IconNeed help?

Do you have a question about the Trane Technologies 4TWV8049A1000B and is the answer not in the manual?

Trane Technologies 4TWV8049A1000B Specifications

General IconGeneral
BrandTrane Technologies
Model Number4TWV8049A1000B
CategoryHeat Pump
SEER Rating18
HSPF Rating10
Refrigerant TypeR-410A
Voltage208/230 V
Phase1
Unit Weight280 lbs

Summary

Service Facts

Variable Speed ComfortLink™ II Heat Pumps and Air Conditioners

Lists specific models of variable speed heat pumps and air conditioners.

SAFETY SECTION — OUTDOOR

Hazardous Voltage Warning

Warning about electrical hazards and lockout/tagout procedures.

Refrigerant Handling Precautions

Details on R-410A refrigerant, PVE oil, and system handling.

Hot Surface Caution

Caution regarding hot surfaces, specifically the compressor.

Refrigerant Pressure Warning

Warning about refrigerant under pressure and recovery procedures.

Grounding Requirements

Importance of proper grounding devices and their reinstallation.

Service Valve Warning

Warning about abrupt release of system charge from service valves.

Brazing and Leak Testing

Guidelines for brazing and leak testing mechanical connections.

High Leakage Current Warning

Warning about high leakage current and earth connection.

SAFETY SECTION — OUTDOOR

400 Volts Electrical Hazard

Warning about high voltage and waiting periods before servicing.

Approved Unit Combinations

Lists compatible indoor units and accessories for variable speed systems.

Outdoor Coil Cleaning Caution

Cautionary notes on cleaning the outdoor coil to protect electrical components.

Operating Range

Specifies the operating temperature ranges for cooling and heating.

Product Specifications - Heat Pump Models

Heat Pump Model Specifications

Table detailing specifications for Heat Pump models.

Product Specifications - Heat Pump Models Continued

Heat Pump Model Specifications Continued

Continues the table of specifications for Heat Pump models.

Product Specifications - Air Conditioner Models

Air Conditioner Model Specifications

Table detailing specifications for Air Conditioner models.

Product Specifications - Air Conditioner Models Continued

Air Conditioner Model Specifications Continued

Continues the table of specifications for Air Conditioner models.

Subcooling Charging Procedure

Charging for Ambient Temperatures

Prescribes subcooling charging for matched systems with indoor TXVs/EEVs.

Subcool Charging Correction Charts

R-410A Refrigerant Charging Chart

Table providing R-410A refrigerant charging data based on liquid temperature.

Subcool Charging Correction Charts

Weigh-In Method for Charging

Details the weigh-in method for system charging.

Wiring Diagram and Legend

Wiring Diagram Legend

Explains the symbols and wire colors used in the wiring diagram.

Wiring Diagram Notes

Provides important notes regarding power supply and wiring compliance.

IVSC Inputs and Outputs

J5 External Outdoor Temperature Sensor

Describes the function and connection of the outdoor temperature sensor.

J10 Electronic Expansion Valve (EEV)

Describes the function and connection of the electronic expansion valve.

J2 Communicating Display Assembly (CDA)

Describes the function and connection of the communicating display assembly.

J9 Condensor Fan Speed Signal

Describes the fan speed signal connection.

J8 Latching Switchover Valve (LSOV)

Describes the LSOV connection.

T5/T6 High Pressure Cut Out (HPCO)

Describes the HPCO connection and function.

J1 and J4 Connections

Describes other key connection points on the IVSC board.

IVSC Board LED Indicators and Sump Heat Control

LED Indicators

Table detailing LED indicators, their rates, descriptions, and indications.

Sump Heat Control Guidelines

Explains sump heat control guidelines and operation.

Sequence of Operation - Overview and Cooling

Control Operational Overview

Overview of the IVSC, communication, and system data flow.

Cooling Mode (A/C and Heat Pump)

Details the operation of the system in cooling mode.

Sequence of Operation - Heating and Defrost

Heat Pump Heating Mode of Operation

Details the operation of the system in heating mode.

Defrost Mode from Cycling-Stage

Explains the defrost mode initiation from cycling stage.

Defrost Mode from Modulating-Stage

Explains the defrost mode initiation from modulating stage.

Defrost Control

Demand Defrost Operation

Explains how demand defrost is measured and determined.

Fault Identification and Defrost Enable

How fault conditions are indicated and defrost is enabled.

Defrost Initiation Logic

How defrost initiation is calculated based on temperature differences.

CDA Navigation to Forced Defrost

Illustrates the menu path for initiating forced defrost.

Sensors - Compressor Dome Temperature

Compressor Dome Temperature Readings

Details the Compressor Dome Temperature Sensor, its readings, and connections.

Sensors - Ambient Temperature

Ambient Temperature Sensor (ODS) Details

Details the Ambient Temperature Sensor, its readings, and required functions.

Sensors - Coil and Suction Temperature

Coil Temperature Sensor Details

Details the Coil Temperature Sensor, its readings, and functions.

Suction Temperature Sensor Details

Details the Suction Temperature Sensor, its readings, and functions.

Sensors - Suction Line Pressure

Suction Line Pressure Transducer Details

Details the Suction Line Pressure Transducer, its readings, and required functions.

Variable Speed Alert Codes

Control Failure Alerts

Lists alert codes related to control failures and their causes.

Variable Speed Alert Codes

High Pressure Monitor Faults

Lists alerts for high pressure monitor faults and their causes.

Ground Fault Alerts

Lists alerts for ground faults and their causes.

Communication Alerts

Lists alerts related to communication errors and their causes.

Variable Speed Alert Codes

Sensor Fault Alerts

Lists alerts related to sensor faults and their causes.

Variable Speed Alert Codes

Parameter and Communication Faults

Lists alerts for parameter and communication issues.

Variable Speed Alert Codes

Drive Current Failure Alerts

Lists alerts related to drive current failures.

Variable Speed Alert Codes

Inverter Temperature Failure Alerts

Lists alerts for inverter temperature failures.

Supply Voltage Failure Alerts

Lists alerts for supply voltage failures.

Variable Speed Alert Codes

Drive Failure Alerts

Lists alerts related to drive failures (gate, motor, stall).

Variable Speed Alert Codes

Initialization and Configuration Alerts

Lists alerts for initialization and configuration errors.

Startup Algorithm Faults

Lists alerts related to startup algorithm failures.

Protection Algorithm Faults

Lists alerts for protection algorithm faults.

Variable Speed Alert Codes

Protection Algorithm Faults (Continued)

Continues listing protection algorithm fault codes.

Variable Speed Alert Codes

Protection Derating Faults

Lists alerts related to protection derating faults.

Variable Speed Alert Codes

Protection Derating Faults (Continued)

Continues listing protection derating fault codes.

Variable Speed Alert Codes

MOC Protection Derating Faults

Lists MOC protection derating fault codes.

Evacuation Mode Alerts

Lists alerts related to evacuation mode.

Variable Speed Alert Codes

MOC Internal Error Alerts

Lists MOC internal error alerts.

Control Board Temperature Alerts

Lists alerts for control board temperature issues.

Variable Speed Alert Codes

OD Fan Faults

Lists alerts related to outdoor fan faults.

Unit Bus Faults

Lists alerts for unit bus communication faults.

Keypad Error

Describes keypad error conditions.

Refrigeration Circuits

2 Ton HP Refrigeration Circuit

Shows the refrigeration circuit for a 2-ton heat pump.

3 Ton HP Refrigeration Circuit

Shows the refrigeration circuit for a 3-ton heat pump.

Refrigeration Circuits

4 Ton HP Refrigeration Circuit (Model 1)

Shows the refrigeration circuit for a 4-ton heat pump.

4 Ton HP Refrigeration Circuit (Model 2)

Shows the refrigeration circuit for another 4-ton heat pump.

Refrigeration Circuits

5 Ton HP Refrigeration Circuit

Shows the refrigeration circuit for a 5-ton heat pump.

2 Ton A/C Refrigeration Circuit

Shows the refrigeration circuit for a 2-ton air conditioner.

Refrigeration Circuits

3 Ton A/C Refrigeration Circuit

Shows the refrigeration circuit for a 3-ton air conditioner.

4 Ton A/C Refrigeration Circuit

Shows the refrigeration circuit for a 4-ton air conditioner.

Refrigeration Circuits

5 Ton A/C Refrigeration Circuit

Shows the refrigeration circuit for a 5-ton air conditioner.

Load Shedding

External Shutdown Function

Explains the function of external shutdown for load shedding.

IVSC Load Shed Connections

Shows the IVSC board and its connection points for load shedding.

Communication Loss Troubleshooting

Troubleshooting No LEDs Lit

Troubleshooting steps for when no LEDs are lit.

Breaker Trip Procedure

Breaker Trip Diagnosis Flowchart

Flowchart for diagnosing breaker trips and related faults.

Start Compressor Troubleshooting

Drive Current Failures and Compressor Start

Steps for troubleshooting drive current failures and compressor start issues.

Compressor Verification

Verify PM and Compressor Model Match

Steps to verify compressor parameters and model match.

Run Drive Diagnostic Test

Drive Diagnostic Test Flowchart

Flowchart for running and interpreting the drive diagnostic test.

Compressor Verification - Short Circuits

Verify Compressor Short Circuit

Procedure for verifying compressor shorts.

Compressor Verification - Open Circuits

Verify Compressor Open Circuit

Procedure for verifying compressor winding opens.

Inverter Temperature Faults

Excessive Rectifier/Inverter Temperature

Identifies causes and actions for excessive rectifier/inverter temperature.

EEV Troubleshooting

EEV Valve Stuck Closed Troubleshooting

Troubleshooting steps for a stuck closed EEV.

EEV Valve Stuck Open Troubleshooting

Troubleshooting steps for a stuck open EEV.

EEV Sensor Calibration Issues

Procedure to check EEV sensor calibration.

Communicating Display Assembly (CDA)

CDA Home Screen and Status

Describes the home screen layout and system status display.

Technician Monitor Menu - System Data

System Status and Sensor Readings

Displays system status, demand, speed, and sensor readings.

Technician Monitor Menu - Drive and Tachometer Data

Drive Parameters

Shows drive parameters like power, voltage, amps, and temperatures.

System Tachometer Data

Displays system run times and cycle counts.

Technician Alert Menu

Active Alerts Display

Shows currently active alerts and their details.

Technician Alert History Menu

Alert History Log

Displays stored alerts, counts, and time since occurrence.

Technician Configuration Menu

System Configuration Options

Lists configurable system parameters and options.

Blower and EMI Notes

Notes on blower delays and EMI settings.

Technician Control Menu - Tests

Run Drive Diagnostic Test

Initiates the drive diagnostic test.

Outdoor Fan Test Procedure

Procedure for running the outdoor fan test.

Technician Control Menu - Specific Tests

Forced Defrost Test Notes

Notes on performing the forced defrost test.

EEV Test Mode Notes

Notes for performing EEV tests.

LSOV Test Notes

Notes for performing LSOV tests.

Evacuation Mode Notes

Notes for executing the evacuation mode.

TECH CONTROL - Charging Modes

Charge/Check Charge Mode Notes

Notes on initiating and using charging modes.

Pressure Curves - 4TWV8024A

4TWV8024A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8024A.

Pressure Curves - 4TWV8036A

4TWV8036A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8036A.

Pressure Curves - 4TWV8037A

4TWV8037A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8037A.

Pressure Curves - 4TWV8048A

4TWV8048A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8048A.

Pressure Curves - 4TWV8049A

4TWV8049A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8049A.

Pressure Curves - 4TWV8060A

4TWV8060A Cooling Pressure Curves

Displays cooling pressure curves for model 4TWV8060A.

Pressure Curves - 4TTV8024A

4TTV8024A Cooling Pressure Curves

Displays cooling pressure curves for model 4TTV8024A.

Pressure Curves - 4TTV8036A

4TTV8036A Cooling Pressure Curves

Displays cooling pressure curves for model 4TTV8036A.

Pressure Curves - 4TTV8037A

4TTV8037A Cooling Pressure Curves

Displays cooling pressure curves for model 4TTV8037A.

Pressure Curves - 4TTV8048A

4TTV8048A Cooling Pressure Curves

Displays cooling pressure curves for model 4TTV8048A.

Pressure Curves - 4TTV8060A

4TTV8060A Cooling Pressure Curves

Displays cooling pressure curves for model 4TTV8060A.

Sound Data - Sound Power

A-Weighted Sound Power Levels

Table showing sound power levels for various models and conditions.

Sound Data - Sound Pressure

Sound Pressure Levels (dBA)

Table showing sound pressure levels at different distances.

Sound Data Summary

Sound Power Levels Summary

Continues table of sound power levels.

Sound Pressure Levels Summary

Continues table of sound pressure levels.

Warranty Claim Process

Integrated Variable Speed Control (Drive) Warranty

Process for warranty claims related to the variable speed control drive.

Pre-Authorization Steps

Steps required for obtaining pre-authorization for warranty claims.

Related product manuals