VAV-SVX08U-EN
7
Digit 12, 13, 14, 15 — Controls
(continued)
DD87 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- Modulating)
DD88 = UC210 DDC- Basic plus- Local
(Water heat- N.O. 2-position) Remote
(Water- N.O. 2-position)
DD89 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- N.C. 2-position)
DD90 = UC210 DDC- Basic plus- Local
(Water heat- N.O. 2-position) Remote
(Water- N.C. 2-position)
DD91 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- N.O. 2-position)
DD92 = UC210 DDC- Basic plus- Local
(Electric heat- Staged) Remote (Staged EH)
DD93 = UC210 Ventilation Flow (Water heat-
N.O. 2-position)
DD95 = UC210 Basic (Electric Heat
Modulating SCR)
DD96 = UC210 Basic plus- Local (Electric
heat-Modulating SCR) Remote (Staged EH)
DD97 = UC210 Ventilation Flow (Electric
heat-Modulating SCR)
ENCL = Shaft Only in Enclosure
FM00 = Other Actuator and Control
FM01 = Trane Supplied Actuator, Other Ctrl
N.C. = Normally-Closed
N.O. = Normally-Open
FM = Factory Installation of Customer-
supplied Controllers
SE71 = Symbio 210e DDC- Basic (Cooling
only)
SE72 =Symbio 210e DDC- Basic (Water heat
- N.C. 2-position)
SE73 =Symbio 210e DDC- Basic (Water
heat-Modulating)
SE74 =Symbio 210e DDC- Basic (Electric
heat - Staged)
SE75 =Symbio 210e DDC- Basic (Electric
heat - PWM)
SE76 =Symbio 210e DDC- Ventilation flow
(no reheat)
SE77 =Symbio 210e DDC- Basic (Water heat
- N.O. 2-position)
SE79 =Symbio 210e DDC- Flow track
(Cooling only)
SE80 =Symbio 210e DDC- Ventilation flow
(N.C. 2-position)
SE81 =Symbio 210e DDC- Ventilation flow
(Electric heat - Staged)
SE82 =Symbio 210e DDC- Ventilation flow
(Water heat-Modulating)
SE83 =Symbio 210e DDC- Basic plus Local
(Electric heat - PWM) Remote (Staged)
SE84 =Symbio 210e DDC- Basic plus Local
(Water heat Modulating) Remote (Water N.C.
2-position)
SE85 =Symbio 210e DDC- Basic plus Local
(Water heat Modulating) Remote (Water N.O.
2-position)
SE86 =Symbio 210e DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote
(Water-Modulating)
SE87 =Symbio 210e DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote
(Water-Modulating)
Digit 12, 13, 14, 15 — Controls
(continued)
SE88 =Symbio 210e DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote (Water
N.O. 2-position)
SE89 =Symbio 210e DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote (Water
N.C. 2-position)
SE90 =Symbio 210e DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote (Water
N.C. 2-position)
SE91 =Symbio 210e DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote (Water
N.O. 2-position)
SE92 =Symbio 210e DDC- Basic plus Local
(Electric heat - Staged) Remote (Staged)
SE93 =Symbio 210e DDC -Ventilation flow
(water heat - N.O. 2-position)
SE95 =Symbio 210e DDC- Control with
modulating SCR
SE96 =Symbio 210e DDC- Space temp
control with local SCR and remote stage
electric heat
SE97 =Symbio 210e DDC- Vent flow with
SCR electric heat
SY71 = Symbio 210 DDC- Basic (Cooling
only)
SY72 =Symbio 210 DDC- Basic (Water heat -
N.C. 2-position)
SY73 =Symbio 210 DDC- Basic (Water heat-
Modulating)
SY74 =Symbio 210 DDC- Basic (Electric heat
- Staged)
SY75 =Symbio 210 DDC- Basic (Electric heat
- PWM)
SY76 =Symbio 210 DDC- Ventilation flow (no
reheat)
SY77 =Symbio 210 DDC- Basic (Water heat -
N.O. 2-position)
SY79 =Symbio 210 DDC- Flow track (Cooling
only)
SY80 =Symbio 210 DDC- Ventilation flow (N.
C. 2-position)
SY81 =Symbio 210 DDC- Ventilation flow
(Electric heat - Staged)
SY82 =Symbio 210 DDC- Ventilation flow
(Water heat-Modulating)
SY83 =Symbio 210 DDC- Basic plus Local
(Electric heat - PWM) Remote (Staged)
SY84 =Symbio 210 DDC- Basic plus Local
(Water heat Modulating) Remote (Water N.C.
2-position)
SY85 =Symbio 210 DDC- Basic plus Local
(Water heat Modulating) Remote (Water N.O.
2-position)
SY86 =Symbio 210 DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote
(Water-Modulating)
SY87 =Symbio 210 DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote
(Water-Modulating)
SY88 =Symbio 210 DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote (Water
N.O. 2-position)
SY89 =Symbio 210 DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote (Water
N.C. 2-position)
SY90 =Symbio 210 DDC- Basic plus Local
(Water heat - N.O. 2-position) Remote (Water
N.C. 2-position)
Digit 12, 13, 14, 15 — Controls
(continued)
SY91 =Symbio 210 DDC- Basic plus Local
(Water heat - N.C. 2-position) Remote (Water
N.O. 2-position)
SY92 =Symbio 210 DDC- Basic plus Local
(Electric heat - Staged) Remote (Staged)
SY93 =Symbio 210 DDC -Ventilation flow
(Water heat - N.O. 2-position)
SY95 =Symbio 210 DDC- Control with
modulating SCR
SY96 =Symbio 210 DDC- Space temp control
with local SCR and remote stage electric heat
SY97 =Symbio 210 DDC- Vent flow with SCR
electric heat
Digit 16 — Insulation
A = 1/2-in. Matte-faced
B = 1-in Matte-faced
D = 1-in Foil-faced
F = 1-in Double Wall
G = 3/8-in Closed-cell
Digit 17, 18— Not Used
00 = Not Applicable
Digit 19— Outlet Plenum (Slip-and-
Drive Connection
0 = None
A = 1 Outlet RH
B = 1 Outlet END
C = 1 Outlets, LH
D = 2 Outlets, 1RH, 1END
E = 2 Outlets, 1LH, 1END
F = 2 Outlets, 1RH, 1LH
H = 3 Outlets, 1LH, 1RH, 1END
J = 4 Outlets, 1LH, 1RH, 2END
Note: See unit drawings for outlet sizes/
damper information.
Digit 20— Not Used
0 = Not Applicable
Digit 21— Water Coil
0 = None
1 = 1 Row
2 = 2 Row
3 = 3 Row
4 = 4 Row
A = 1 Row Premium
B = 2 Row Premium
C = 3 Row Premium
D = 4 Row Premium
MMooddeell NNuummbbeerrss