EasyManua.ls Logo

Trane 4TTR3018H - Section 5. Refrigerant Line Considerations

Trane 4TTR3018H
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 18-AC79D1-10D-EN
Section 5. Refrigerant Line Considerations
5.1 Refrigerant Line and Service Valve Connection Sizes
Table 5.1
RATED
LINE SIZES
Line Sizes Service Valve Connection Sizes Max Line & Lift Lengths
Vapor
Line
Liquid
Line
Vapor Line
Connection
Liquid Line
Connection
TOTAL Max
Line Length (ft.)
Max Lift (ft.)
4TTR3018N
3/4 3/8 3/4 3/8
150 50
4TTR3024N
3/4 3/8 3/4 3/8
150 50
4TTR3030N
3/4 3/8 3/4 3/8
150 50
4TTR3036N
3/4 3/8 3/4 3/8
150 50
4TTR3042N
7/8 3/8 7/8 3/8
150 50
4TTR3048N
7/8 3/8 7/8 3/8
150 50
4TTR3060N
7/8 3/8 7/8 3/8
150 50
Note: For other line lengths, Refer to Refrigerant Piping Application Guide, SS-APG006-EN or Refrigerant Piping
Software Program, 32-3312-xx (latest revision).
4TTR3018H
3/4 3/8 3/4 3/8
150 50
4TTR3024H
3/4 3/8 3/4 3/8
150 50
4TTR3030H
3/4 3/8 3/4 3/8
150 50
4TTR3036H
3/4 3/8 3/4 3/8
150 50
4TTR3042E
7/8 3/8 7/8 3/8
150 50
4TTR3043A
7/8 3/8 7/8 3/8
150 50
4TTR3048E
7/8 3/8 7/8 3/8
150 50
4TTR3049A
7/8 3/8 7/8 3/8
150 50
4TTR3060E
7/8 3/8 7/8 3/8
150 50

Related product manuals