EasyManuals Logo

Trane AM4A0A30S21SA Series User Manual

Trane AM4A0A30S21SA Series
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
30
STEP 4 - Make connections per hookup diagrams.
Air Handler Hook-up Diagram
Cooling
Red
Yellow
Green
White
Blue
Yellow
Green
White
Blue
B
B - Blue
Blue
W
G
Y
Y - Yellow
Yellow
R
Red
O
Orange
Comfort Control
Air Handler
Air Conditioner
Field wiring
O **
R **
B
YI
W1
YO
G
W2
W3 *
* For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.
** R to O jumper must be in place as shown for cooling only, non-heat pump systems for proper operation.
YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly.
Internally mounted condensate switch is optional and must be ordered separately.
If 3rd party condensate overflow switches are installed, they should be wired between Y of the thermostat and YI of the EEV control.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane AM4A0A30S21SA Series and is the answer not in the manual?

Trane AM4A0A30S21SA Series Specifications

General IconGeneral
BrandTrane
ModelAM4A0A30S21SA Series
CategoryAir Handlers
LanguageEnglish

Related product manuals