EasyManua.ls Logo

Trane BAYECON086A User Manual

Trane BAYECON086A
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
January 2010
ACC-SVN44D-EN
Installers Guide
Economizer
Packaged Rooftop Units
Model Number: Used With:
BAYECON085A TSC/YSC036E-060E*R WSC060EDR
THC/YHC036E*R
WSC036E-048E*R
BAYECON086A THC/YHC036E*E TSC/YSC036E-060E*E
BAYECON087A THC/YHC048E-120E*R WSC060E(3/4/W)R
TSC072E-120E*R WSC072E-120E*R
YSC072E-120E*R
BAYECON088A THC/YHC048E-120E*E
TSC072-120E*E
YSC072-120E*E
Question and Answer IconNeed help?

Do you have a question about the Trane BAYECON086A and is the answer not in the manual?

Trane BAYECON086A Specifications

General IconGeneral
BrandTrane
ModelBAYECON086A
CategoryAir Conditioner
LanguageEnglish

Summary

Warnings, Cautions and Notices

Important Environmental Concerns!

Discusses man-made chemicals' impact on the ozone layer, focusing on refrigerants.

Responsible Refrigerant Practices!

Emphasizes technician certification and adherence to laws for responsible refrigerant handling.

Personal Protective Equipment (PPE) Required!

Details mandatory PPE for installation/servicing due to potential electrical, mechanical, and chemical hazards.

Installation

Model Number Description

Explains model number identification for unit type, operation, and component specification.

Parts List

Lists all components included with the economizer assembly for installation purposes.

Installation - Field Installed

Covers the installation process for specific BAYECON model numbers and compatible units.

Downflow Installation

Instructions for assembling the end panel to the economizer for downflow configurations.

Horizontal Installation

Instructions for assembling the end panel to the economizer for horizontal configurations.

Optional Sensors (ReliaTel Only)

Guides for installing optional humidity and temperature monitoring sensors for ReliaTel units.

Blockoff Assembly

Procedures for installing the return duct blockoff plate before economizer installation.

Mixed Air Sensor Installation

Instructions for installing the Mixed Air Sensor with grommet and wire tie.

Wiring Connections ReliaTel Units

Describes connecting unit wiring harness plugs for ReliaTel units.

Electromechanical Unit Wiring

Instructions for connecting the unit wiring harness plug for electromechanical units.

Factory Installed Economizer Set-Up

Steps for setting up a factory-installed economizer for proper operation.

Downflow Economizer Configuration

Specific steps to position and secure the economizer for downflow operation.

Horizontal Economizer Configuration

Specific steps to position and secure the economizer for horizontal operation.

Minimum Position Setting

Procedure to adjust the economizer damper's minimum ventilation position.

Dry Bulb Settings

Explains field-selectable dry bulb changeover settings for the economizer.

Reference Enthalpy Settings

Details field-selectable enthalpy changeover settings for the economizer.