1.2.1
Symbols
•
This publication contains the following symbols:
Danger
Draws attention to actions that can cause serious injury if not performed
correctly.
Prohibited
Draws attention to actions that impose a prohibition.
1.3
Range
1.3.1
Available versions
1.4
Accessories
Factory fitted accessories
Automatic circuit breakers
Cooling circuit shut-off valve on discharge line
Cooling circuit shut-off valve on liquid line
3-Way electronic pressostatic valve for evaporation control
3-Way electronic pressostatic valve for cold start
Modbus RTU protocol, RS485 serial interface
Modbus TCP/IP protocol, Ethernet port
BACnet MSTP protocol, RS485 serial interface
BACnet TCP/IP protocol, Ethernet port
LonWorks protocol, FTT-10 serial interface
SNMP protocol, Ethernet port
Remote set-point, 0-10 V signal
Remote set-point, 4-20 mA signal
Remote signal for second set-point activation
Demand limit from digital input
0-10 V signal for the management of the 3-Way electronic pressostatic valve for
0-10 V signal for the management of the 3-Way electronic pressostatic valve for cold
Loose accessories
High and low pressure gauges
1.5
Compliance
The device complies with the following regulations:
•
Machinery Directive 2006/42/CE
•
PED Directive 2014/68/EU
•
Electromagnetic Compatibility Directive 2014/30/UE
•
LVD Directive: 2014/35/UE
•
Energy Using Product directive 2009/125/EU and implementing regulations
1.6
Machine identification
The equipment can be identified from:
•
Packaging plate.
-
It shows the identification data of the equipment.
•
Frame feature plate.
-
Affixed on the machine, it shows the technical and performance data of the equipment.
•
Electrical board feature plate.
-
Affixed on the panel from which the electrical board is accessed, it shows the electrical
data of the equipment.
If it is lost or deteriorated, request a duplicate from Technical Support.
Tampering with, removal and deterioration of the identification plates complicate any
installation, maintenance and spare part request.
1.7
Intended use
This unit is designed to heat water (possibly added with inhibited ethylene glycol) which
circulates in a closed circuit.
The hot water produced can be used for air conditioning systems or for industrial processes.
The machine cannot be installed outdoors.
Any other use of the machine is forbidden.
Do not use flammable products near the machine.
Do not use substances that can form explosive mixtures close to the machine.
Do not use the machine where there are problems of environmental impact.
Frame feature plate
Electrical board feature plate