1/16”
(1.2)
SERVICE PANEL
LINE VOLTAGE
CONTROL WIRING
SUCTION LINE
LIQUID LINE
SERVICE PANEL SIDE
4 5/16” (109)
1 5/16” (33)
2 13/16” (72)
3 3/16” (81)
9 5/16”
(236)
16 5/16”
(415)
27 13/16”
(706)
35 3/8”
(898)
6”
(152)
6”
(152)
33 13/16”
(859)
21 11/16”
(551)
33 15/16”
(863)
35 15/16”
(913)
WITH HAIL GUARD
1 7/8” (47)
2 7/8” (74)
40 15/16”
(1039)
42”
(1067)
WITH HAIL GUARD
20 15/16”
(531)
39 1/16”
(993)
17 7/16”
(442)
11 13/16”
(300)
3” (76)
34 3/4”
(886)
40 3/4”
(1036)
1 13/16” (47)
27 11/16”
(704)
2 5/16” (59)
2 5/16” (59)
SERVICE PANEL
SERVICE CLEARANCE
48” (1219.2) (SEE NOTE 2
FOR CLEARANCE)
SEE NOTE 1
REFRIGERANT GUAGE ACCESS
CONTROL
WIRING
(OPTIONAL)
7/16” (11.11) DIA. ISOLATOR MOUNTING
HOLES (OUTSIDE HOLES - 4 PLACES)
BOTTOM
OF UNIT
SEE NOTE 4
HAIL GUARD
(OPTIONAL)
HAIL GUARD
(OPTIONAL)
SEE NOTE 3
NOTES:
1. ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY.
2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36” ( 914.4) FROM
WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE
BETWEEN ADJACENT UNITS IS 72” (1828.8). RECOMMENDED SERVICE
CLEARANCE 48” (1219.2)
3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100” (2540)
MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER OR FALLING
SNOW FROM ROOF DOES NOT POUR/FALL DIRECTLY ON UNIT
4. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING)