EasyManuals Logo

Trane P0V0 Series User Manual

Trane P0V0 Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
P0V0-SVX001-1A-EN
23
R
W2
G
W1
B/C
O
Y2
Y1
BK
W2
G
W1
O
Y2
Y1
BK
Indoor Unit
Relay Panel
Communicating
Control
HUM
HUM
AUX1
AUX1
AUX2
AUX2
W3
STG2
FAN
STG1
SOV
D
R
B
STG2
STG1
PWM
HUM
HUM
AUX1
AUX1
AUX2
AUX2
STG3
24V
ONLY
24V
ONLY
24V
ONLY
D
R
B
COMMUNICATING CONTROLS WITH NON-COMMUNICATING MODULAR BLOWER
AND COMMUNICATING VS COOLING/HP
D
R
B
Outdoor Unit
NOTES:
1. Cut the BK jumper at the indoor unit - After cutting the jumper, power must
be off or cycled on-off-on for the IMBC to work properly
2. Requires an 850 control with software version 3.0+ or 1050 control. Not
a valid combination with 950 control.
CPC=CFM/Ton cooling. Must be set to 400.
Control Board LED’s will read “CoF“ continous fan during cooling and heat
pump operation.
3. To connect optional devices (such as a float switch) wire in series from
indoor unit "R" to relay panel "R".
24 V Field Wiring
Condensate
Switch
GGeenneerraall IInnssttaallllaattiioonn

Other manuals for Trane P0V0 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane P0V0 Series and is the answer not in the manual?

Trane P0V0 Series Specifications

General IconGeneral
BrandTrane
ModelP0V0 Series
CategoryBlower
LanguageEnglish

Related product manuals