Instructions on storing and maintaining the manual for accessibility and proper use.
Explanation of symbols used to indicate hazards, prohibitions, and important information.
Guidelines and regulations for worker safety and essential personal protective equipment.
Explanation of safety signs and key warnings for handling R32 refrigerant.
Information on R32 refrigerant hazards, safety data, disposal, transport, and storage.
Specifies the minimum and maximum temperature limits for unit transport and storage.
Guidelines for safely lifting and handling the unit by qualified personnel.
Requirements for unit placement, support, and necessary clearances for proper operation and safety.
Detailed dimensions and clearance requirements for Picco R32 06A, 08A, and SL08A models.
Detailed dimensions and clearance requirements for Picco R32 10, 10T, 12, SL12, 12T, SL12T models.
Detailed dimensions and clearance requirements for Picco R32 14, 14T, 16, SL16, 16T, SL16T, 18T models.
Procedure for accessing the internal components of the Picco R32 06A, 08A, and SL08A models.
Procedure for accessing the internal components of the Picco R32 10, 10T, 12, SL12, 12T, SL12T models.
Procedure for accessing the internal components of the Picco R32 14, 14T, 16, SL16, 16T, SL16T, 18T models.
Maximum allowed chemical-physical properties for the circuit water to ensure correct operation.
Procedures for filling, discharging the system, and function of air venting valves.
Description of condensate drainage and location/use of service sleeves.
A recommended connection diagram and reference to a system handbook.
Refrigerant circuit diagram for Picco R32 06A, 08A, and SL08A models.
Refrigerant circuit diagram for Picco R32 10, 10T, 12, SL12, 12T, SL12T models.
Refrigerant circuit diagram for Picco R32 14, 14T, 16, SL16, 16T, SL16T, 18T models.
Procedure for accessing the electric panel for wiring and maintenance operations.
Guidelines for connecting the unit to the power supply, emphasizing qualified personnel and regulations.
Details on terminal connections for power supply, remote control, and sensors.
Reference to the manual for detailed information on unit control logic and parameters.
Information on fuse types and nominal specifications for the unit.
Step-by-step instructions for safely switching on the unit after installation and checks.
Detailed instructions for cleaning the unit's finned coils, including methods and precautions.
Specific instructions for cleaning finned coils with anti-corrosion treatment.
Guidelines for cleaning the unit's outer casing to prevent corrosion and maintain appearance.
Information that extraordinary maintenance must be carried out by authorized service centers.
Checks on refrigerant charge, ventilation, lines, and components for system integrity.
Safety checks for electrical components, including discharging capacitors and earth connection.
Procedures and precautions for working on sealed components and enclosures.
Inspection of wiring for wear, corrosion, tension, and vibration effects.
Safe methods for detecting refrigerant leaks, avoiding open flames and ignition sources.
Suitable processes for detecting leaks using electronic or liquid leak detectors.
Procedures for removing and evacuating refrigerant, including purging with inert gas.
Requirements for safely charging refrigerant, including system checks and labeling.
Detailed steps for safely decommissioning the unit, including refrigerant recovery and component disposal.
Instructions for labeling the heat pump when taken out of use, indicating status and refrigerant.
Best practices for recovering refrigerants, including equipment, cylinders, and safety.
Detailed technical specifications for standard Picco R32 units, including cooling, heating, and electrical data.
Technical specifications for silenced version Picco R32 units, detailing performance and electrical data.
Details on unit power supply, controller circuits, and fan power supply for various models.
Minimum and maximum permitted water flow rates for the evaporator to ensure proper operation.
Permissible water temperatures for cooling mode, including minimum evaporator outlet and maximum steady state.
Permissible water temperatures for heating mode, including inlet, outlet, and safety considerations.
Allowed ranges for outdoor air temperature in different operating modes (cooling, heating, DHW).
Explanation of the unit's interface display, status LEDs, and the functions of the control buttons.
Description of menu items, labels, password levels, and access conditions.
Details on settable parameters for summer, winter, and DHW setpoints, and mixing valve settings.
Information on how the alarms menu is displayed and how alarms are categorized by circuit.