EasyManua.ls Logo

Trane S9V2B040U3VSAE - 15 Fault Code; 17 Fault Code

Trane S9V2B040U3VSAE
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112
S9V2-VS-SVX001-1B-EN
DEFINITION:
This fault is generated when the PM
and the IFC informa!on is corrupted
15 Fault Code
Disconnect power
Possible causes
PM corrupted
Faulty IFC
Disconnect power
Is 4 pin motor
communica!on
connector installed
and fully seated on
the IFC?
Install and/or fully
seat
NO
DEFINITION:
This fault is generated when IFC does
not see a return signal from the blower
motor
17 Fault Code
Is 9 pin connector at
the blower ves!bule
panel installed and
fully seated?
YES
Install and/or fully
seat
NO
Is 4 pin connector at
the blower installed
and fully seated?
Install and/or fully
seat
NO
YES
Verify con!nuity of all
motor wiring and replace
motor if required
YES
TTrroouubblleesshhoooottiinngg