SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
July 2022
SS99VV22--SSVVXX000011--11AA--EENN
Upflow/Horizontal and Dedicated Downflow
Gas-Fired, Direct/Non-Direct Vent, 2-Stage
Condensing Variable Speed Furnaces
UUppffllooww,, CCoonnvveerrttiibbllee ttoo
HHoorriizzoonnttaall RRiigghhtt oorr
HHoorriizzoonnttaall LLeefftt
S9V2B040U3PSBC/D
S9V2B060U4PSBC/D
S9V2B080U4PSBC/D
S9V2C080U5PSBC/D
S9V2C100U5PSBC/D
S9V2D120U5PSBC/D
DDoowwnnffllooww OOnnllyy
S9V2B040D3PSBC/D
S9V2B060D3PSBC/D
S9V2B080D4PSBC/D
S9V2C100D5PSBC/D
S9V2D120D5PSBC/D
NNoottee:: Graphics in this document are for
representation only. Actual
model may differ in appearance.
CAUTION
!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit.
COIL REQUIREMENT!
Installation, Operation, and Maintenance

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Trane S9V2B060D3PSBC/D and is the answer not in the manual?

Trane S9V2B060D3PSBC/D Specifications

General IconGeneral
ModelS9V2B060D3PSBC/D
CategoryFurnace
TypeGas
Efficiency RatingHigh Efficiency
AFUE96%
Heating Capacity60, 000 BTU
Input BTU60, 000 BTU
Output BTU57, 600 BTU
Blower TypeVariable Speed
StagesTwo-Stage
Fuel TypeNatural Gas
BrandTrane
Motor TypeECM
Warranty10-Year Limited Warranty

Summary

General Safety Warnings

Furnace Installation Guidelines

Safety Practices and Precautions

Essential safety measures for installation, servicing, and operation.

Wiring Diagram

Furnace General Installation

Gas Piping

Procedures and requirements for connecting the gas supply to the furnace.

Combustion and Input Check

Steps for verifying proper combustion and gas input rates.

General Venting

Requirements and best practices for furnace venting systems.

Electrical Connections

Instructions for making proper electrical connections to the furnace.

Condensate Drain Instructions

General Start-up and Adjustment

Preliminary Inspections

Initial checks to ensure readiness before starting the furnace.

Control and Safety Switch Adjustment

Steps for adjusting and verifying controls and safety switches.

Furnace Combustion Air Exhaust Options

Upflow Furnace in Upflow Position - Top Vented Combustion Air

Instructions for top venting combustion air in upflow furnace configuration.

Upflow Furnace in Upflow Position - Left Side Vented Combustion Air

Instructions for side venting combustion air in upflow furnace configuration.

Upflow Furnace in Horizontal Left Position - Side Vented Combustion Air

Instructions for side venting combustion air in horizontal left upflow furnace.

Downflow Furnace - Top Vented Combustion Air

Instructions for top venting combustion air in downflow furnace configuration.

Downflow Furnace - Left Side Vented Combustion Air

Instructions for side venting combustion air in downflow furnace configuration.

Integrated Furnace Control Menu

Integrated Furnace Control Display Codes

Error Codes

List and explanation of error codes for troubleshooting.

Troubleshooting

01 Fault Code

Troubleshooting steps for internal IFC failures.

2.1 Fault Code

Troubleshooting steps for flame sensing and gas pressure issues.

3.1 Fault Code

Troubleshooting steps for PS1 (pressure switch) issues.

3.2 Fault Code

Troubleshooting steps for inducer motor and PS1 issues.

3.3 Fault Code

Troubleshooting steps for PS2 orientation and voltage issues.

3.4 Fault Code

Troubleshooting steps for PS2 motor running and pressure issues.

Periodic Servicing Requirements

Related product manuals