SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
December 2022
SS99VV22--VVSS--SSVVXX000011--11BB--EENN
Upflow/Horizontal and Dedicated Downflow
Gas-Fired, Direct/Non-Direct Vent, 2-Stage
Condensing Variable Speed Furnaces with Variable Speed
Draft Inducer
UUppffllooww,, CCoonnvveerrttiibbllee ttoo
HHoorriizzoonnttaall RRiigghhtt oorr
HHoorriizzoonnttaall LLeefftt
S9V2B040U3VSAE
S9V2B060U3VSAC/D
S9V2B080U4VSAC/D
S9V2C100U4VSAC/D
S9V2D120U5VSAC/D
DDoowwnnffllooww OOnnllyy
S9V2B080D4VSAC/D
S9V2C100D4VSAC/D
NNoottee:: Graphics in this document are for representation
only. Actual model may differ in appearance.
CAUTION
!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit.
COIL REQUIREMENT!
S9V2-VS-SVX001-1B-EN
Installation, Operation, and Maintenance
Question and Answer IconNeed help?

Do you have a question about the Trane S9V2B080D4VSAD and is the answer not in the manual?

Trane S9V2B080D4VSAD Specifications

General IconGeneral
ModelS9V2B080D4VSAD
TypeGas Furnace
Heating Capacity80, 000 BTU
Blower TypeVariable Speed
BTU Input80, 000 BTU
Gas TypeNatural Gas
StagesTwo-Stage
Warranty10 Years Limited

Summary

Product Overview and Safety Information

Critical Safety Warnings

Highlights critical safety information and requirements.

Safety Section and Precautions

Fire, Electrical, and CO Hazards

Covers warnings related to fire, explosion, electrical, and CO hazards.

Gas Piping and Combustion Setup

Combustion, Input Check, and Valve Adjustment

Covers combustion checks, input rates, and gas valve adjustments.

Venting System Installation

General Venting Rules and Terminations

Covers general venting, special cases, and termination requirements.

Electrical Connections and Wiring

Main Wiring Diagram

Provides the primary electrical wiring diagram for the furnace.

Condensate Drain Instructions

General Start-up and Adjustment

Integrated Furnace Control System

Menu Navigation and Settings

Explains IFC menu, settings, and status codes.

Fault Code Recovery Procedures

Steps to view, clear, and reset fault codes.

Troubleshooting and Maintenance

Related product manuals