80 RT-SVX24J-EN
Table 23. Electrical service sizing data—motors
Condenser Fan Motors
Nominal
Tons No. of Fans
460 V 575 V 380 V
FLA FLA FLA
90, 105 6 16.2 13.2 15
120, 130,
150
8 21.6 17.6 20
100 2 11.8 N/A N/A
118, 128,
140, 162
2 11.8 N/A N/A
Supply Fan Motors
Motor
Horsepow
er
460 V 575 V 380 V
FLA FLA FLA
15 18.5 15.1 24
20 24.7 19.6 29
25 31 24.5 38
30 36.6 29.2 47
40 49.0 39 54
50 60.5 48 68
60 71.5 57.2 81
75 90 72 103
100 115 92 N/A
Exhaust/Return Fan Motors
Motor
Horsepow
er
460 V 575 V 380 V
FLA FLA FLA
7.5 9.4 7.8 13.6
10 12.6 10.1 16
15 18.5 15.1 24
20 24.7 19.6 29
25 31 24.5 38
30 36.6 29.2 47
40 49.0 39 54
50 60.5 48 68
60 71.5 57.2 81
Table 24. Electrical service sizing data—electric heat
module (electric heat units only)
Voltage
460 575 380
Module kW FLA FLA FLA
90 / 56 108.3 86.6 85.1
140 / 88 168.4 134.7 133.7
265 / 166 318.8 255 252.2
300 / 188 360.8 288.7 285.6
Table 25. Electrical service sizing data—control power
transformer (heating mode only)
Nominal Tons
Digit 2 Unit
Function
Voltages
460 575 380
FLA FLA FLA
90-150/100-162 E, L, S, X 3 3 4
90, 105/100, 118 F (850 MBH) 4 4 5
90, 105/100, 118 F (1100 MBH) 4 4 5
90, 105/100, 118 F (1800 MBH) 4 4 5
120-150/128-162 F (1100 MBH) 4 4 5
120-150/128-162 F (1800 MBH) 4 4 5
120-150/128-162 F (2500 MBH) 4 4 5
Table 26. Electrical service sizing data—crankcase heater
Nominal Tons
Voltage
460 575 380
FLA (add)
FLA
(add)
FLA
(add)
90-162 1 1 1
Table 27. Voltage utilization range
Unit Voltage
460/60/3 414-506
575/60/3
(a)
(a)Units with air-cooled condensers only.
517-633
380/50/3
(i)
342-418
Table 28. Electrical service sizing data—evaporative
condenser
Unit Part kw HP
Voltage
460
FLA
Pump
1.5 2.7
Sump Heater
3 3.8
Table 29. Electrical service sizing data—energy recovery
wheel motor
Nominal Tons Unit Function
Voltages
460 575
FLA FLA
90-128 1 (Low CFM ERW) 1.2 0.95
130-162 1 (Low CFM ERW) 1.7 1.4
90-162 2 (Std. CFM ERW) 1.7 1.4