22
TK 53050-3-OP-EN
Specifications
APPLICATION Control of HVAC unit
SETUP TEMPERATURE RANGE 17 °C (63 °F) to 27 °C (80 °F)
Display in °C and °F as firmware option
OPERATING VOLTAGE RANGE 10 - 32 VDC
CURRENT CONSUMPTION Max. 100 mA
OPERATING TEMPERATURE RANGE
-40 °C (-40°F) to 80 °C (176 °F)
CONNECTION
RS232 serial connection
CAN bus - CAN0, CAN1
DIMENSIONS (WxHxD) 120 mm x 180 mm x 35 mm (without cover)
POWER SUPPLY
Ready 24 VDC
INPUTS Analogue (AI) - 14
Digital (DI (4)
OUTPUTS Analogue (AO) - 4
Digital (DO) - 17
DIAGNOSTIC / PROGRAMMING
CANDiag software
CCAANNAAIIRREE CCoonnttrroolllleerr