12
Service Facts
X343070P08
To Pin #12
To Pin #15
To Pin #1 & #3
24 V.A.C.
#9 PIN WIRE IS ORANGE
#1 PIN WIRE IS BLUE
These service procedures will work on ECM-2
TM
motors and their motor
control board and their 16 Wire Low Voltage Control Cable.
Jumper
Q
uick
C
heck
M
otor
W
ill
N
ot
R
un
ECM -2
TM
QUICK CHECK
B
lower
M
otor
W
ill
N
ot
R
un
1. J
umper
24 V
olt
A.C. "R" T
erminal
to
"G"
terminal
on
the
L
ow
V
oltage
T
erminal
board
.
D
oes
motor
run
?
NO:
Go to step #2.
YES:
Motor runs,
check Comfort Control
and Comfort Control wire.
2. U
nplug
16
wire
low
voltage
harness
from
the
interface
board
.
J
umper
24 V
olts
A.C.
to
pins
#12, #15
and
common
pins
#1
and
#3.
D
oes
the
motor
run
?
NO:
Go to step #3.
YES:
Replace the
variable speed
interface board
on the furnace.