33601 Rev. D www.transition.com Page 1 of 25
SGFEB10xx-xxx
10/100/1000 Bridging Media Converter
User Guide
Auto Negotiation / AutoCross / Link Pass Through / Port Isolation
Provides rate conversion while also increasing transmission distances
Supports multimode or single mode fiber
Table of Contents
Introduction.................................................................................................................................................... 2
Package Contents ......................................................................................................................................... 2
Model Numbers ............................................................................................................................................. 2
Optional Accessories (sold separately) ......................................................................................................... 3
Distances....................................................................................................................................................... 3
Applications ................................................................................................................................................... 4
Installation ..................................................................................................................................................... 5
Configuration............................................................................................................................................. 5
One DIP Switch Layouts ...................................................................................................................... 6
Two DIP Switch Layouts ...................................................................................................................... 7
Power Connection .................................................................................................................................... 8
Port Locations and Layouts ...................................................................................................................... 9
Installing the RJ-45 Copper Cable .......................................................................................................... 10
Installing the Fiber Cable ........................................................................................................................ 10
Operation..................................................................................................................................................... 11
Status LEDs ............................................................................................................................................ 11
Product Features .................................................................................................................................... 12
Auto-Negotiation ................................................................................................................................. 12
Link Pass-Through (LPT) ................................................................................................................... 12
Full-Duplex Network ........................................................................................................................... 12
Half-Duplex Network (512-Bit Rule) ................................................................................................... 12
AutoCross™ ....................................................................................................................................... 13
Automatic Link Restoration ................................................................................................................ 13
Far End Fault (FEF)............................................................................................................................ 13
Remote Fault Detect (RFD) ................................................................................................................ 13
Fiber Redundancy (Revertive / Non-revertive) ................................................................................... 13
New Features ..................................................................................................................................... 13
Port Isolation ....................................................................................................................................... 14
Energy Efficient Ethernet (EEE) ......................................................................................................... 16
Cable Specifications .................................................................................................................................... 17
Copper Cable Specs ............................................................................................................................... 17
TP Port Specs ......................................................................................................................................... 17
Fiber Cable Specs .................................................................................................................................. 18
Technical Specifications ......................................................................................................................... 19
Warnings ................................................................................................................................................. 20
Model Number Cross Reference ................................................................................................................ 21
Troubleshooting .......................................................................................................................................... 22
Contact Us................................................................................................................................................... 23
Compliance Information .............................................................................................................................. 24
Record of Revisions .................................................................................................................................... 25
Question and Answer IconNeed help?

Do you have a question about the Transition Networks SGFEB10 Series and is the answer not in the manual?

Transition Networks SGFEB10 Series Specifications

General IconGeneral
BrandTransition Networks
ModelSGFEB10 Series
CategoryMedia Converter
LanguageEnglish

Summary

Installation

Configuration

Explains DIP switch layouts and their importance for device configuration.

One DIP Switch Layouts

Two DIP Switch Layouts

A. 6-Position DIP switch

Explains the 6-position DIP switch for dual SFP port models.

4-Position DIP Switch (on SFP versions, Port 3 populated)

Describes the 4-position DIP switch settings for SFP versions.

Switches 3 and 4

Details the functionality of DIP switches 3 and 4 for SFP versions.

Power Connection

Installing the RJ-45 Copper Cable

Installing the Fiber Cable

Operation

Status LEDs

Explains the various status LEDs for monitoring SGFEB operations.

Fiber Status LEDs

Details the meaning of LACT and DUP LEDs for fiber connection status.

Copper Status LEDs

Describes the TP Link/Activity/Duplex and Speed LEDs for copper ports.

Product Features

Auto-Negotiation

Explains automatic configuration of speed and duplex for optimal link operation.

Link Pass-Through (LPT)

Describes the LPT feature for propagating link loss signals to the far end.

AutoCross TM

Automatic Link Restoration

Details the device's ability to automatically restore links after fault conditions.

Far End Fault (FEF)

Explains the FEF feature for detecting and signaling fiber link faults.

Remote Fault Detect (RFD)

Describes the RFD feature for monitoring and reporting fiber link failures.

Port Isolation

Port Isolation on 4-Port Models

Energy Efficient Ethernet (EEE)

Fiber Cable Specs

Technical Specifications

Warnings

Laser safety standards

Outlines Class 1 laser product safety standards and compliance requirements.

Troubleshooting

Contact Us

Related product manuals