Features:
- Maximum 20,000 BTU Input
- Removable Rain Cap
- Tempered Glass (easy to remove and clean)
- Stainless Steel Construction
- Automatic Gas Shutoff Valve for Safety
- Rotary Piezo Igniter for Easy Lighting
- Wet Weather Lighting Port for Positive Ignition
Installation Options:
- For Outdoor Installation Only
- For Fixed Line Installations Only
- Wall Mount
- Post Mount
- Pier Mount
Specifications:
NG LP
Input Rating (Btuh) High - Low 20,000 – 14,000 20,000 – 17,500
Orifice Size (DMS) #50 #55
Burner Ports 25 Holes 49 Holes
Manifold Pressure 7" wc 11" wc
Max. Inlet Pressure 7" wc 11" wc
Dimensions:
NOTE: All Clearances are measured from the glass (and glass frame).
8-7/8”
2-1/2”
19-1/2”
9-1/2”
8-7/8”
9-1/2”