Installation (for qualified installers only) 7
© Travis Industries, Inc. 4050608 100-01203_000
Placement Requirements
! For Outdoor Use Only. Install in well-ventilated areas.
Do Not Locate the Torch:
• In high traffic areas.
• Under or near trees, plants and buildings where debris may constantly fall into the torch.
Excessive debris will require high maintenance and/or cause malfunctioning of the torch.
• In places where people, children, and pets may contact the torch. Guards or fences
around the torch in these locations are recommended.
• In places where the controls beneath the torch may be submerged under water.
Submerging of any part of its controls will require complete replacement of the controls.
Clearances:
• The distance from ground level to the base of the burner shall be a minimum of 7 ft. (2.1M)
where installed within 2 feet (0.6M) of public walkways (e.g.: sidewalk, shared walkway
between two homes, or pathway in commercial applications). Lesser clearances shall be
permitted to be used only where acceptable to the authority having jurisdiction.
• Keep combustibles away from the shaded heat zone of the torch (see illustration below).