Model 301SP Tube Squaring Machine
92-0579 Rev. 190612 13
7. Run the Clamp Knob Assy in until it lightly presses the second
SaddlehalfagainsttherstSaddlehalf.
8. Thread the Shoulder Screw in through the Clamp Knob Assy into
the upper half Saddle.
9. Retract the second Saddle half by turning the clamp Knob Assy.
10. Install the two Insert Nuts with the two Flat Washers into the front of
the Housing.
11. Insert the tubing to be worked on into the front of the Model 301SP.
12. Move the tube or pipe approximately 1/16” (1.6 mm) from the tool bit.
13. Tighten the Clamp Knob Assy to tighten the tube in the Saddle.
14. Connect the Model 301SP to the power source and pull the Trigger
to start rotation of the Cutting Head.
15. If the Machine has a Metabo Motor, use the Speed Control in the
Trigger Guard to adjust the cutting speed.
CAUTION
CAUTION: Do not let the tool bit touch the tube or pipe. This will damage the tool bit
or the Tube Squaring Machine when power is applied.
Feed
Handle
Speed
Control
Trigger
Figure: 6. Milwaukee Motor Controls