12
D01-068en201913 Manual TpH
Calibration // TpH
Use
Use
Calibration
Calibration
Malfunction &
Maintenance
Malfunction &
Maintenance
Commissioning
Commissioning
Introduction
Introduction
General
Information
General
Information
FAQ
FAQ Technical Data
Technical Data
Warranty
Warranty
Customer
Service
Customer
Service
Contact
Contact
Keyword Index
Keyword Index
Accessories
Accessories
The pH value depends on temperature!
NOTICE
Rinse the sensor again with distilled water.
Immerse the TpH in pH4 buer solution, the sensor head (black) should be immersed as completely as possible
(the picture below shows the immersion depth in the beaker with the buer solution as a red line). Otherwise,
measurement uctuations may occur.
Allow the sensor to warm up for approx. 5 minutes and then calibrate to pH4 (or pH10). Observe the temperature!
Rinse the sensor with distilled water.
You can now begin your measurements.
Dispose the buer solutions after use.
Immerse the sensor slowly into the small buer solution and move it slightly so the membrane is wetted by the
buer solution.
Allow the sensor to warm up for approx. 5 minutes and then calibrate to pH7. Observe the temperature!
Optimum immersion depth in applica-
tion with TriOS buer solution.
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Name: TpH
Date: 23.02.2018 Rev.: TP101711
Note: Dimensions in mm
Document: D10-068en201805
TriOS Mess- und Datentechnik GmbH
Bgm.-Brötje-Str. 25 26180 Rastede Germany
fon: +49 4402 / 69 67 0 - 0
fax: - 20 web: http://www.trios.de e-mail: info@trios.de
Dimension Drawing: TpH
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung seines Inhalts sind verboten,
soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten.
The reproduction, distribution an
d utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved.
Page 1 of 1
Note: iProperty -> Übersicht -> Kommentar
Preliminary: iProperty -> Status -> Status
Titel: iProperty -> Übersicht -> Titel
23
~
27
~
138~
36,5~
AF = across flats
178~
Position Material
sensor body
Polyethylene Terephthalate (PET)
Polyphenylene Sulfide (PPS)
sealings
Nitrile Butadiene Rubber (NBR)
pH Stem pH Sensing Glass