SPECIFICATION
Electrical
Nominal Power Rating at 240V
Nominal Power Rating at 230V
Supply Fuse/Miniature Circuit
Breaker (MCB)
Residual Current Device (RCD)
Isolation Switch
Supply Cable
9.0kW 10.5kW
8.3kW 9.6kW
40Amps 45Amps
30mA 30mA
45Amp Double Pole isolating switch
(with 3mm minimum contact gap)
16mm² Maximum
(refer to ‘Electrical Requirements’)
Water Supply
Supply Type
Minimum Pressure (Dynamic)
Maximum Pressure (Static)
Inlet Water Temperature
Inlet Water Connection
Outlet Water Connection
Ambient Temperature
Battery (within Tri-HUB)
Mains pressure cold water only
70kPa (0.7 bar)
1000kPa (10 bar)
2°C - 28°C
15mm Stem
(suitable for push-t and compression ttings)
15mm Stem
(suitable for push-t and compression ttings)
Accreditations
Directive – Policy Statement
a producer and a supplier of electric showers, Triton Showers is committed to the protection of the environment
our own environmental policy and the compliance with the WEEE directive.
riton Showers is fully registered with the Environment Agency under the following schemes:
Repic:
Producers take-back scheme (PTS), registration number WEE/EJ3466QV
our electric products are labelled accordingly with the crossed out wheeled bin symbol. This indicates, for
purposes at end of life, that these products must be taken to a recognised collection points, such as
authority sites/local recycling centres; this will be free of any charges.
Do not return to Triton Showers.
Valpak: Distributor take-back scheme (DTS), registration number DTS-501317-1
5°C to 40°C