Fig.8
The PRD is situated behind the outlet pipe
(fig.6). To access the PRD, FIRST SWITCH OFF
THE ELECTRICITY SUPPLY, unscrew the hose
then remove the cover. Remove the two screws
holding the outlet pipe to the base of the can.
Carefully pull away from the can and then
unscrew the two screws holding the PRD to the
outlet pipe.
CAUTION: Do not attempt to replace the PRD
unless competent to do so.
Note: Before replacing the cover, it is strongly
advised to prime the unit (see ‘commissioning’).
Fig.7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton T90xr and is the answer not in the manual?

Triton T90xr Specifications

General IconGeneral
TypeElectric Shower
Power Ratings8.5kW, 9.5kW
Temperature ControlStabilised
Shower Head Spray Patterns5
FinishWhite
Warranty2 years
Water Entry PointsTop, Bottom, Back
Cable Entry PointsTop, Bottom, Back
InstallationWall Mounted
Water PressureMinimum 1 bar, Maximum 10 bar
Spray Modes5
Shower Hose Length1.25 meters