EasyManuals Logo

Triton VALDI User Manual

Triton VALDI
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Vertical bar mixer shower
11
FINAL LEAK TESTING
Fit the hose to the outlet and direct it to waste.
Open the isolating valves to the shower and
check for leaks. Remedy any leaks found.
COMMISSIONING
Important: Make sure that all supply pipework
has been flushed through before commissioning.
Start the water flow by rotating the flow control
Make sure that both the hot and cold water
supplies are fully open and at (or near to) their
design temperature and pressures, and are within
the requirements as stated.
Make sure the temperature control is at the
maximum temperature setting.
Allow the shower to run at the maximum
temperature setting until the water temperature
has stabilised. Rotate the temperature control
until your desired maximum showering
temperature is reached.
The mixer has a temperature stop to prevent
accidental rotation to higher temperatures. This
is adjustable to provide a maximum temperature
of 35°C – 45°C and should be checked on site to
guarantee user safety.