EasyManuals Logo

Triton VALDI User Manual

Triton VALDI
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Vertical bar mixer shower
13
Recommended outlet temperatures
The BuildCert TMV scheme recommends the
following set maximum mixed water outlet
temperatures for use in all premises:
44°C - for bath fill but see notes below.
41°C - for showers.
41°C - for washbasins.
38°C - for bidets.
The mixed water temperatures must never
exceed 46°C at terminal fitting.
The British Burns Association recommends 37 to
37.5°C as a comfortable bathing temperature
for children. In premises covered by the Care
Standards Act 2000, the maximum mixed water
outlet temperature is 43°C.
OPERATING THE SHOWER
To start the mixer, rotate the On/Off flow
control (bottom lever) clockwise until it stops
for maximum flow (fig.12).
To stop the water flow, rotate the On/Off
flow control anti-clockwise until it stops
(fig.12).
To adjust the water temperature, rotate the
temperature control (top lever) – clockwise
for colder or anti-clockwise for hotter
(fig.13).
Fig.13
Flow control
Temperature
control
Fig.12
OFF
ON
HOTTER
COLDER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triton VALDI and is the answer not in the manual?

Triton VALDI Specifications

General IconGeneral
BrandTriton
ModelVALDI
CategoryPlumbing Product
LanguageEnglish

Related product manuals