EN 5
oil heater IDE 20 / IDE 30 / IDE 50 / IDE 60 / IDE 80
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Switch the device off and disconnect it from the
mains.
2. Remove persons from the danger area.
3. Do not reconnect a defective device to the mains.
Overheating protection
The device is provided with a safety thermostat which is
activated by overheating of the device (when exceeding the
operating temperature).
Investigate the cause of overheating.
If the safety thermostat does not switch in the event of
overheating, the overheating protection will be tripped. In that
case the device switches off completely. If so, please contact
the customer service to have the overheating protection
replaced.
Information about the device
Device description
The indirectly fired oil heatersIDE20,IDE30,IDE50,IDE60
and IDE80 serve the purpose of heating the room air so as to
quickly heat large rooms.
The devices only run on ELfuel oil or diesel, they must not be
used with petrol, heavy fuel oil etc.
The devices are oil heaters with indirect combustion to be
installed in roofed outdoor areas or in rooms with a sufficient
fresh air supply. The devices are equipped with an exhaust gas
connection for the discharge of exhaust gases via the chimney.
The devicesIDE30,IDE50,IDE60 and IDE80 are additionally
equipped with a fuel filter and a Danfoss pump.
Functional principle
The device generates warmth by conveying the sucked-in, cold
air past the enlarged area of the combustion chamber, the heat
exchanger. The air to be heated is completely isolated from the
combustion chamber, where the fuel is burned. The combustion
products are discharged into the open air through a flue pipe.
The sucked-in air is heated and fed back to the environment via
the air outlet.