8EN
convector TCH 1 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•Switch the device off.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
•Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
ParameterValue
ModelTCH 1 E
Heating capacity450W
Mains connection220–240V~50Hz
Power consumption0.45 kW
Nominal current
consumption
2A
Fusing10A
Plug typeSchuko plug CEE7/7
Cable length1.2 m
Dimensions
(lengthx widthx height)
177x 275x 276 mm
Minimum distance to walls
and other objects
top(A):
rear(B):
sides(C):
front(D):
100 cm
50 cm
50 cm
50 cm
Weight1 kg