EasyManua.ls Logo

Trotec TTK 25 E - Condensation Tank Management

Trotec TTK 25 E
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B - 8 Operating Manual – Dehumidifier TTK 25 E EN
"Continuous" operation mode
In continuous operation mode, the device dehumidi-
fies the air constantly, regardless of the humidity in
the air.
To start continuous operation mode, keep pressing
the key (11) until the "Continuous" indicator light (15)
is lit.
Automatic defrost
If the room temperature is below 12 °C, the evapora-
tor becomes covered in frost during dehumidification.
In that event the device carries out an automatic de-
frost. The "Defrost" indicator light (14) is lit.
Emptying the condensation tank
A.
C.
B.
D.