dehumidifier TTK 53 E / TTK 72 E
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Laundry drying mode
The device may be used to dry clothes in a more timely manner.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The device dehumidifies the air constantly and regardless of the
relative room humidity. The fan runs at the highest speed.
The relative room humidity and the fan speed cannot be set in
this operating mode.
1. Press the MODEbutton(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the DRY CLOTHES
indication(21) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð The laundry drying function is selected.
ð The DRY CLOTHESindication (21) is illuminated.
For drying laundry the following values should be selected:
cupboard dry=46% relative humidity
iron dry= 58% relative humidity
slightly dried= 65% relative humidity
If necessary, use a measuring device to determine the humidity
level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
If necessary, remove the condensation drain hose and any
residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Transport and storage
chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Note
Wait for at least 3minutes after maintenance and
repair work. Only then switch the device back on.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check the filling level of the condensation tank and empty
it if necessary. The Tank Full indication(23) must not light
up.
Check the condensation tank for correct seating.
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
The device is running, but there is no formation of
condensate:
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check the air filter for dirt. If necessary, clean or replace
the air filter.
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.