EN 9
dehumidifier TTK 53 E / TTK 72 E
The fan runs at low speed and the fan speed cannot be
changed.
1. Press the MODEbutton(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS
indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Dehumidification mode is selected.
ð The CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) to adjust the relative room
humidity.
5. Wait for approx. 5seconds in order to save the setting.
For setting the relative room humidity
You can only change the relative room humidity in
dehumidification mode.
1. Press the arrow buttons(12, 14) to adjust the relative room
humidity. Setting is possible in the range between 30%
and 80% in increments of 5%.
ð The desired relative room humidity is indicated in the
segment display(13) for approx.5seconds. Then the
current relative room humidity is displayed again.
Colour LED for current room humidity
Regardless of the operating mode, the colour LED indicates the
current relative room humidity by means of 3 different colours.
LED colour Meaning
Blue
Relative room humidity below 55%
Green
Optimal relative room humidity between 55%
and 70%
Red
Illuminated: relative room humidity above 70%
Flashes: water tank full or not inserted correctly
(accompanied by an acoustic signal)
Continuous operation mode
The device dehumidifies the air constantly and regardless of the
relative room humidity.
The fan runs at low speed and the fan speed cannot be
changed.
1. Press the MODEbutton(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS
indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð The CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) until CO is indicated in the
segment display(13).
5. Wait for approx. 5seconds in order to save the setting.
ð Continuous operation(20) is selected.
Automatic operation
The relative room humidity is preset to 55 % and cannot be
changed.
If the relative room humidity lies between 55 % and 70 %, the
fan automatically switches over to low speed.
Below a relative room humidity of 55%, the compressor
switches off.
Above a relative room humidity of 70 %, the fan runs at the
highest level.
1. Press the MODEbutton(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AUTOMATIC
indication(19) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Automatic mode is selected.
ð The AUTOMATICindication (19) is illuminated.
Ventilation
The fan runs at low speed. The compressor does not run.
1. Press the MODEbutton(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AIR CLEAN
indication(22) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Ventilation mode is selected.
ð The AIR CLEANindication (22) is illuminated.
Setting the timer
Using the timer function, the device can be switched off
automatically after a preset number of hours.
The number of hours can range from 1 to 24 and can be
adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(11).
ð The segment display(13) flashes.
2. Press the arrow buttons(12, 14) to set the desired number
of hours.
3. Wait for approx. 5seconds in order to save the setting.
ð The TIMERindication (24) is illuminated.
ð The relative room humidity is indicated in the segment
display(13) again.
ð The device switches off after the set period of time.