TROU B LES H OOTi NG
Probmem
No AC output is avaHabme, but
generator is running.
Generator runs good at no=moad
but "bogs" down" when loads are
connected.
Generator will not start; or starts
and runs rough.
Cause
I. One of the circuit breakers is
open.
Z Fault in generator.
3. Poor connection or defective cord
set.
4. Connected device is bad.
[. Short circuit in a connected load.
Z Generator is overloaded.
3. Shorted generator circuit.
I. I0 Amp in:line fuse is blown.
2. Discharged battery.
Correction
[. Reset circuit breaker.
2. ContactAuthorized service facility.
3. Check and repair.
3. Failed battery.
Generator shuts down during Out of gasoline.
operation.
Generator lacks power. Load is too high. See "Don't Overload Generator".
4. Connect another device that is in
good condition.
I. Disconnect shorted electrical load.
2. See "Don't Overload Generator".
3. ContactAuthorized service facility.
I. Replace fuse.
2. Jump start generator and/or charge
battery.
3. Replace battery.
Fill fuel tank.