2
Installation example
1 Truma-Boiler
2 Control panel
3 Safety/drain valve
4 Cowl for combustion air intake
and exhaust gas discharge
General safety notes
In event of leaks in the gas system or if there is a smell of gas:
extinguish all naked flames
do not smoke
switch off all appliances
shut off the gas cylinder
open the windows and doors
do not actuate any electrical switches
have the entire system checked by an expert!
Repairs may only be carried out by an expert.
Danger: Failure to operate the relief valve easing gear at least
once every six months may result in the water heater splitting.
Continuous leakage of water from the valve may indicate a
problem with the water heater!
Water may drip from the discharge pipe of the pres sure relief
device and this pipe must be left open to the atmosphere.
– The pres sure relief device is to be operated regularly to
remove lime deposits and to verify that it is not blocked.
Any discharge pipe connected to the safety (pres sure relief)
valve is to be installed in a continuously downward direction
and in a frost free ambient.
This unit is not to be used by children or infirm persons
without proper supervision at all times. Not to be used as a
toy.
Before gaining access to any and all terminals, please ensure
all supply circuits are disconnected (i.e. 230 – 240 V and
12 V) and gas supply is securely turned off.
Any work involving connection or interconnecting wiring
must be conducted by a licensed electrician.
Any alteration to the appliance (including cowl) or the use
of spare parts and accessories which are important for the
functioning of the heater and which are not original Truma
parts, as well as the non-observance of the installation and
operating instructions, shall lead to the cancelling of the
guarantee and exclusion of liability claims. It also becomes
illegal to use the appliance, and in some countries this even
makes it illegal to use the vehicle.
The operating pressure for the gas supply is 2.75 kPa
(propane) and must correspond to the operating pressure
of the appliance (see data plate).
LPG Systems and pressure regulators must comply with
the technical and administrative regulations of the country
in which the appliance is used. For your own safety it is
absolutely necessary to have the complete gas installation
regularly checked by an expert (at least every 2 years).
The vehicle owner is always responsible for arranging
the gas inspection.
Do not operate when travelling.
Do not operate the water heater when refuelling the vehicle
and when in the garage.
Items sensitive to heat (e.g. spray cans) must not be stored
in the installation area, since excess temperatures may under
circumstances be incurred there.
During the initial operation of a brand new appliance (or
after it has not been used for some time), a slight amount of
fumes and a slight smell may be noticed for a short while.
Remedial action here is to immediately run the heater and to
ensure adequate room ventilation.
If the burner makes an unusual noise or if the flame lifts off,
it is likely that the gas pressure regulator is faulty and it is
essential to have it checked.
Boiler B 10 / B 14
Liquid gas storage water heater
(Special version BN 10 / BN 14
with additional electric heating 230 V, 850 W)