7 Cleaning and care
7.1 Cleaning the cowl outer part
To prevent adhesion of combustion residues, Truma rec-
ommends regular cleaning of the cowl outer part�
To clean it, use a soft sponge and a plastic cleaning
product for the outside area�
NOTICE
Damage to the heater caused by water in
the wall cowl
When cleaning the vehicle with a high-pres-
sure water blaster, avoid the area around the
wall cowl�
7.2 Cleaning the water container
If the water container is not used for long periods,
legionella and other microorganisms can breed in
standing water
Regularly sterilise and descale the water container of
the heater� All cleaning products from camping special-
ists are suitable for cleaning, sterilisation and care�
We also recommend that you heat the water in the wa-
ter container to 70 °C regularly to prevent microorgan-
isms breeding�
Select “Diesel” mode�
Set water temperature to 60 °C�
Switch on device�
Once the water in the water container has reached a
temperature of 60 °C, the burner will switch off� Leave
the appliance switched on for at least 30 minutes and
do not draw any hot water� The residual heat in the
heat exchanger will heat the water up to 70 °C�
To descale the water container, use commercial descal-
ing products, vinegar essence or citric acid�
Fill the water container with cleaning or descaling prod-
ucts in the correct mixing ratio via the water inlet and
allow them to work�
Then rinse the water container thoroughly with clean
water
8 Maintenance and servicing
If the Combi D is filled with water, heat it at least
once per month for approx� 30 min� (see “Cleaning
the water container”)�
The safety / drain valve ( FrostControl) must be op-
erated regularly (at least twice annually) to remove
limescale deposits and to be certain that it is not
blocked�
8.1 Fuses
8.1.1 Fuses 12 V
DANGER
Risk of fire from short circuit
In the event of a short circuit in the 12 volt pow-
er supply, very high currents can flow and cause
cable fires�
Replace fuses only with the battery
disconnected
DANGER
Risk of fire if an
unsuitable fuse is used
May be replaced only with a Truma original
part (part number 34020-01331)
The fuses (Fig� 11-3) are located on the electronics
(Fig� 11-2) beneath the connector cover (Fig� 11-1)�
Disconnect all poles from the battery
Remove the connector cover
Replace the fuses�
Replace faulty fuses only with Truma original parts�
Replace the connector cover
Reconnect the battery
1
3
2
3
Fig� 11