6-60 4BPneumatic components B380EN06.DOC
4.3 Maintenance instructions
Pressure regulator
(see section 4.2, p. 6-59)
Every 500 op
erating hours.
1 3 42 5
1 Manual shut-off valve 4 Pressure gauge
2 Sight glass 5 Condensation drain plug
3 Pressure regulator
1. Shut down the machine properly, switch off the MAIN
SWITCH, lock it and pull out the key.
2. Check the pressure regulator for an operating pressure of 6.5
bar.
Every 500 operating hours.
1. Shut down the machine properly, switch off the MAIN
SWITCH, lock it and pull out the key.
2. Turn condensation drain plug to the left.
3. Turn condensation drain plug to the initial position.
Check the pressure regulator
Fig. 31592
Drain the condensation water