18
3.8 Replacing the LCD Control Board & LCD Touch Panel
1. Follow the previous step (refer to section 3.7) to remove the LCD panel module.
2. Remove the FPC harness from the LCD control board.
3. Remove the marked six fixed screws (fastened by 5 kg±15% kg-cm) to take out LCD control board, the holder and touch panel can
be removed.Reassemble the parts in the reverse procedures.
Touch panel
LCD control board
Screws location