Safety
41
Safety
Installation
Unless otherwise stated TSL equipment may be installed at any angle or position within an operating
temperature range of 5 ~ 25 degrees C.
The RJ45 connectors are for use only with TSL UMD equipment.
All TSL equipment conforms to the EC Low Voltage Directive:
EC Low Voltage Directive (73/23/EEC) (OJ L76 26.3.73) (LVD).
Amendment: (93/68/EEC) (OJ L220 30.8.93).
Earthing/Grounding
In all cases, the frame of the equipment should be earthed on installation. Connection to an earthed
strip running the length of the frame is ideal.
The earth pin on the IEC mains inlet connector is connected to the metal frame of the equipment, to
0 volts on the internal DC PSU and to signal ground, unless otherwise stated. All metal panels are
bonded together. Rack mounted equipment must be earthed (grounded).
Mounting
Careful consideration of the equipment location and mounting in racks must be made. In particular,
consideration must be given to the stability of free-standing racks by mounting heavy equipment low
in the rack. The rear of the unit should be supported in the rack.
Power
For pluggable equipment, the socket outlet shall be installed near the equipment and shall be easily
accessible.
Consideration must be given to the supply circuit loading and switch on/fault surges that will affect
over current protection trips and switches etc.
Check that the fuse rating is correct for the local power (mains) supply. Replacement fuses must be
of the same rating and type for continued protection against fire risk.
The equipment rating is shown on the rear panel.
No power supply cord is provided with this equipment.
Do not switch on until all connections are made.
Ventilation
Due consideration for cooling requirements must be given when mounting the equipment.
If the equipment is installed in a closed unit, consideration must be given to providing forced air
cooling in order that the maximum recommended temperature is not exceeded. Introduction 9
TallyMan V 1.7.1b on