4.1 Power switch
This pallet truck is equipped with an emergency stop switch,
which is the basic control of this vehicle and is located on the top
of the vehicle body, see Figure 2-1.
Lightly press the emergency stop switch to turn off the power, the
vehicle can not travel. Pull upward, then the button will
automatically move up, i.e., turn on the main power of the vehicle.
Press the off button again, the power is cut off.
Figure 2-1
4.2 Combination lock
The vehicle is equipped with a password lock function, before
entering the authorized password, the machine will not be
allowed to start, in order to prevent unauthorized people from
operating the machine, password lock function can not only
facilitate the use, but also help the machine to prevent theft and
improve security.
Electronic handle handle will enter the standby state after
power on, LCD back light off, according to the handle
configuration, the screen displays the corresponding hour meter
and power information, need to use the correct password to
unlock, then the LCD back light will be lit, in order to manipulate
the vehicle to work normally.
The factory default password for the password lock is 1234, the
operating vehicle can directly use this password to start the
vehicle, the factory default administrator password is 3232, refer
to the following steps to enter and change the password.
4
In standby mode, enter 1234 and press √ to confirm, you
can enter X to rewind one character if you make a mistake.
To change the password in standby mode, enter 3232 and
press the √ key to confirm.
Enter the original password and press the √ key to
confirm.
Enter the new password again and press the √ key to
confirm, the original password will be overwritten.
If you forget your password, you can use the security code
to reset your password.
In standby, enter 123 and press √ to confirm.
Then enter 123 and press √ to confirm, the password is
reset to 1234
4.3 Handle display
Figure 2-2 Figure 2-3
Battery charge indication.
Figure 2-2 shows the display after the battery is
discharged. The last two cells flash when the battery is at its
lowest level and needs to be charged in time.
As Figure 2-3 shows the battery full cell (10 cells) each cell
represents 10% of the power, as the battery is discharged, the
number of cells shown gradually decreases.
5
Emergency
stop switch