4.9 Scale
4.9.1Main Function
》Basic weighing functions: zeroing, tare function
》Accumulation function
》Printer
》Unit exchange function
》Checkweighing function
》Battery voltage indication
》Auto power off and power saving function
4.9.2Parameters
》Sensor excitation voltage:+3.3VDC
》A/D exchange rate:10 次/秒
》Input Signal Range:0—12.8Mv
》Load capacity: up to four 350 ohm sensors
》Unit:KG
》Calibration divisions:3000e
》Selectable indexing values:1/2/5/10/20/50
》Indicator:LCD
》Keyboard: 5 function keys
》Working Temp.:-10~40℃
》Storage Temp.:-20~+60℃
10
4.9 Key function
Long press 3 seconds for starting up when the
instrument is in OFF status. Long press for 3 seconds
for shutdown when the instrument is in ON status.
1.Accumulation operation
2.See the cumulative sums with SET key
Unit switch between Kg and Ib.
The instrument has zero clearing within allowable
zero clearing range. Tare beyond the zero clearing
range. Article weight is the tare and displays the net
weight zero.
1. Calibration with switch key combination
2.Long press for print.
3.Cumulative sum with TOTAL key combination
4.9.1 ON/OFF
Press ON/OFF key for 3 seconds in OFF status. The instrument
will display 888888. It then will have self checking of the
number of strokes. The instrument will display the current
weight after the self-checking.
4.9.2 Zero setting
Press the zero setting tare function if it exceeds the zero range.
The instrument will display the net weight zero. The
instrument is not able to have tare operation when the scale is
in dynamic status and the stable light is not on.
11