Installation
Installation Requirements
Location
1. Position the oven in its approximate working position.
2. The unit should be positioned so that the control panel
and oven shelves are easily reachable for loading and
unloading.
Clearances
To ensure correct ventilation for the motor and controls,
the following minimum installation clearances are to be
adhered to:-
Rear 50mm / 2”.
Left-hand side 50mm / 2”.
Right-hand side
75mm / 3”.
CLEARANCE FROM SOURCE OF HEAT.
A minimum distance of 300mm (12”) from the
appliance sides is required.
NOTE: Fixed installations require at least 500mm - 20”
clearance at the right hand side of oven for
service access.
Stand Mounted Oven
For ovens that are to be mounted to a stand, the oven feet
are used to level the oven on the stand. Refer to the
instructions supplied with separately ordered stands for
mounting details.
Important:
The vent located on the top of the oven must NOT be
obstructed.
Important:
 Installation shall comply with local electrical, health and safety requirements.
 It is most important that this oven is installed correctly and that oven operation is correct before use.
 If you have any questions regarding the proper installation and / or operation of this oven, please contact your local
Turbofan distributor.
Technical Data Plate - Location.
Oven Vent Location
Any questions? Contact us at www.eventservicesgroup.co.uk
Telephone: 03333 442062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the turbofan E32D4 and is the answer not in the manual?

turbofan E32D4 Specifications

General IconGeneral
Brandturbofan
ModelE32D4
CategoryOven
LanguageEnglish

Related product manuals