4 IO-Link Parameters
4.1 General parameters
The general parameter data is used to identify the sensors. This data can only be read.
Address
(hexa-
decimal)
Parameter name Description Value
(hexa-
decimal)
Meaning
04 IO-Link revision ID Imported IO-Link version
07 Vendor ID 1 Vendor ID 01 317 for Hans Turck GmbH & Co. KG
IM/Vendor_ID_Table.xml
08 Vendor ID 2 3D
09 Device ID 1 Device ID
(assigned by the manufacturer)
01
0A Device ID 2 see table
below
0B Device ID 3 see table
below
Device ID 2
Electrical
output
Device ID 2
(hexadecimal)
2UPN: 00
LI2UPN: 01
LUUPN: 02
Device ID 3
Measuring range Device ID 3
(hexadecimal)
01VR: 0x00
001A: 0x01
003A: 0x02
010A: 0x03
016A: 0x04
025A: 0x05
001V: 0x06
003V: 0x07
010V: 0x08
016V: 0x09
025V: 0x0A
040V: 0x0B
001R: 0x0C
100R: 0x0D
250R: 0x0E
400R: 0x0F
600R: 0x10
0.25V: 0x12