Enter the battery memory program, you can change the battery
type(Lipo, Lilo, LiFe, NiMH, NiCd, Pb battery), voltage, charge
current by pressing the Start/Enter button to make the value blink,
the INC or DEC buttons to change the value, and Start/Enter
button once more to store the value and move to the next value or
screen. (Note: The battery used for this example is a 2S(7.4V) Lipo
battery.
Set the voltage and number of cells, along with the normal voltage
(1-8S).
Set the charge current, which can be adjusted(0.1-40.0A).
18 ·
BATTERY MEMORY SET
The charger can store up to 10 different charge/discharge profiles for your convenience,
and the stored profiles can be recalled quickly without having to go through the setup
process.
BATT MEMORY【1】
ENTER SET
BATT TYPE
LiPo
BATT VOLTS
7.4V(2S)
CHARGE CURRENT
4.9A
ENTER
START
DEC INC
>3 seconds
DEC INC
DEC
INC
DEC INC
DEC
INC
DSCH CURRENT
2.2A
Set the discharge current, which can be adjusted(0.1A-8.0A,
each port).
DSCH VOLTAGE
3.0V/CELL
Set the discharge voltage, which can be adjusted(3.0V/CELL-
3.3V/CELL).
TVC=YOUR RISK
4.20V
Set the terminal voltage, which can be adjusted(4.18v-4.30v).
DEC INC
DEC
INC
DEC INC
DEC
INC
DEC INC
DEC
INC
TEMPERATURE
CUT-OFF 50C
DEC INC
DEC
INC
Set the temperature, which can be adjusted(20C-80C).cut-off
Turnigy Mega 1000W