E
MAINTENANCE
34
If an error is occurred in the hydraulic
lifting/lowering system:
1. The type of the error is displayed by
blinking of the status LED on the
control panel.
2. The error code is displayed through
the indicator on the meter panel
simultaneously.
ERROR CODE DISPLAY FOR
HYDRAULIC SYSTEM
When there is an electric or electronic
fault, the indicator (1) blinks according
to the setting in the system to inform
the type of the fault.
To read the error code properly, observe
the number and sequence of blinking of
the indicator (1) carefully.
Read an error code according to the
following steps:
Step 1: The LED on the control panel
stops for approx. 2 seconds
before indicating a code.
Step 2: After a brief stop, it blinks for the
number of the first digit of the
error code at a short interval.
Step 3: After delivering the first digit, it
stops blinking for approx. 1
second.
Step 4: After a brief stop, it blinks for the
number of the second digit of the
error code at a short interval.
The control panel LED displays one
error code with the highest priority
(severe fault) at one time.
To check for any other error codes, this
code with the highest priority should be
cleared. Then, the control panel LED
displays another error code if there is
any.
ERROR CODE DISPLAY OF
CONTROL PANEL STATUS LED
Errors, that prevents the lift controls
from operation, has the highest priority.
CAUTION
STATUS LED (INDICATOR 1)