General Specifications
53
Model UT107: OPERATING MANUAL
Maximum Voltage between any Terminals and
grounding: Refer to different range input protection
voltage.
Fuse Protection of mA
0
C terminal: 315mA,
250V, fast type, 5x20mm
Fuse Protection of A terminal:
10A, 250V, fast type, 5x20mm
Measurement Speed: Updates 2-3 times /second.
Maximum Display: 1999.
Temperature:
Operating: 0
0
C ~40
0
C (32
0
F~104
0
F).
Storage: -10
0
C ~50
0
C (14
0
F~122
0
F).
Relative Humidity: 75% @ 0
0
C to below 30
0
C;
50% @ 30
0
C to 40
0
C.
Altitude: Operating : 2000m; Storage: 10000m.
Battery Type: One piece of 9V (NEDA1604 or 6F22
or 006P).
Electromagnetic Compatibility: In a radio field of 1
V/m, Overall Accuracy = Specified Accuracy + 5% of
Range; in a radio field of more than 1 V/m, no assigned
accuracy is specified
Battery Deficiency: Display .
Negative reading: Display .
Overloading: Display 1.
Equipped with full icons display.
Manual ranging.
Polarity: Automatically display.
Dimensions (HxWxL): 179 x 88 x 39mm.
Weight: 380g. (including holster and battery)
Safety/Compliances: IEC61010: CAT. II 1000V, CAT.
III 600V overvoltage and double insulation standard.
Certification:
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l

Table of Contents