I. AC Current
Range
66.00A
1000A
Resolution
0.01A
1A
Accuracy
(2%+40)
(2%+8)
Overload protection
250VAC
Frequency
Response
50Hz ~ 60Hz
The operating temperature must be 0 ~40 when measuring current.
Remarks:
It may have unstable or wrong sensed readings, it will not affect measurement
result.
Hold the Meter tight, do now release. The Hall components are very sensitive
not only to the magnet but also to heat and machines reaction force. Any shock
will cause the changing in reading in the short time.
Change to AC:
Combine AC and True RMS response method. Input sine wave to adjust.
Warning
Model UT207/208: OPERATING MANUAL