EasyManua.ls Logo

Unic Rumba - Water Softener Regeneration Procedure; Step-by-Step Regeneration Instructions

Unic Rumba
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 11 -
Water Softener Regeneration : how ?
A - Water intake
B - Water outlet
C - Intake tap
D - Outlet tap
E - Discharge pipe
F - Regenerating pipe
G - Lid wheel
Use 1 kg of salt when the
softener is 400 mm high.
Use 2 kg of salt when the
softener is 600 mm high.
INSTRUCTIONS FOR
USE :
Install an empty vessel with
a 2-litre capacity under Pipe E.
Turn Handles C and D from
the left to the right.
Unscrew G to remove the
lid.
Insert salt.
Restore the lid to its initial
position.
Turn Handle C from the right
to the left
Let the salted water run
through Pipe F until it gets
soft.
Turn Handle D from the right
to the left

Table of Contents